| Side Wall Cladding Profile Load Table Proliner 1000/32 |
|
32mm Deep Profile - 1000mm Cover Width
(Material Spec.: Fe E 280 G) |
Applied Load in kN/m2 |
| Span in Metres |
| Section Type: |
Thick. mm |
Load Type: |
1.2 |
1.4 |
1.6 |
1.8 |
2.0 |
2.2 |
2.4 |
2.6 |
2.8 |
3.0 |
| |
| Single
|
0.4 |
Dead + Super |
2.87 |
1.86 |
1.25 |
0.88 |
0.64 |
0.48 |
0.37 |
0.29 |
|
|
| |
Wind Suction |
2.05 |
1.29 |
0.86 |
0.61 |
0.44 |
0.33 |
0.26 |
0.20 |
|
|
| 0.7 |
Dead + Super |
6.32 |
3.98 |
2.67 |
1.87 |
1.37 |
1.03 |
0.79 |
0.62 |
0.50 |
0.41 |
| |
Wind Suction |
4.40 |
2.77 |
1.86 |
1.30 |
0.95 |
0.71 |
0.55 |
0.43 |
0.35 |
0.28 |
| |
| Double |
0.4 |
Dead + Super |
2.59 |
1.90 |
1.46 |
1.15 |
0.93 |
0.77 |
0.62 |
0.49 |
0.39 |
0.32 |
| |
Wind Suction |
2.87 |
2.11 |
1.44 |
1.01 |
0.74 |
0.55 |
0.43 |
0.34 |
0.27 |
0.22 |
| 0.7 |
Dead + Super |
5.81 |
4.27 |
3.27 |
2.58 |
2.09 |
1.71 |
1.32 |
1.04 |
0.83 |
0.67 |
| |
Wind Suction |
6.70 |
4.62 |
3.09 |
2.17 |
1.58 |
1.19 |
0.92 |
0.72 |
0.58 |
0.47 |
| |
| Multiple |
0.4 |
Dead + Super |
3.23 |
2.38 |
1.82 |
1.44 |
1.07 |
0.80 |
0.62 |
0.49 |
0.39 |
0.32 |
| |
Wind Suction |
3.41 |
2.15 |
1.44 |
1.01 |
0.74 |
0.55 |
0.43 |
0.34 |
0.27 |
0.22 |
| 0.7 |
Dead + Super |
7.26 |
5.34 |
4.08 |
3.12 |
2.28 |
1.71 |
1.32 |
1.04 |
0.83 |
0.67 |
| |
Wind Suction |
7.33 |
4.62 |
3.09 |
2.17 |
1.58 |
1.19 |
0.92 |
0.72 |
0.58 |
0.47 |
| |
Deflection: Dead + Super Loads = L/200
Note: All intermediate values within the limits of the table may be obtained by linear interpolation. |
|