Proliner
Roofing Cladding Normal Profile Load Table Proliner 1000/32
Profile Proliner 1000/32
32mm Deep Profile - 1000mm Cover Width (Material Spec.: Fe E 280 G) Applied Load in kN/m2
Span in Metres
Section Type: Thick. mm Load Type: 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0
 
Single

 

0.4 Dead + Super 2.48 1.81 1.21 0.84 0.60 0.44 0.33 0.25    
  Wind Suction 2.09 1.33 0.90 0.65 0.48 0.37 0.30 0.24    
0.7 Dead + Super 5.80 3.92 2.60 1.81 1.30 0.96 0.72 0.55 0.43 0.34
  Wind Suction 4.47 2.84 1.92 1.37 1.02 0.78 0.62 0.50 0.41 0.35
 
Double 0.4 Dead + Super 2.23 1.62 1.24 0.97 0.78 0.64 0.53 0.44 0.35 0.28
  Wind Suction 2.55 1.89 1.45 1.05 0.78 0.59 0.47 0.37 0.31 0.26
0.7 Dead + Super 5.02 3.67 2.79 2.19 1.76 1.45 1.20 0.97 0.76 0.61
  Wind Suction 5.93 4.37 3.16 2.24 1.65 1.26 0.98 0.79 0.64 0.54
 
Multiple 0.4 Dead + Super 2.79 2.04 1.55 1.22 0.98 0.76 0.58 0.45 0.35 0.28
  Wind Suction 3.18 2.19 1.48 1.05 0.78 0.59 0.47 0.37 0.31 0.26
0.7 Dead + Super 6.29 4.60 3.51 2.76 2.21 1.64 1.25 0.97 0.76 0.61
  Wind Suction 7.40 4.68 3.16 2.24 1.65 1.26 0.98 0.79 0.64 0.54
 
Deflection: Dead + Super Loads = L/200
Note: All intermediate values within the limits of the table may be obtained by linear interpolation.