Proliner
Side Wall Cladding Profile Load Table Proliner 1000/20
Profile Proliner 1000/20
20mm Deep Profile - 1000mm Cover Width (Material Spec.: Fe E 280 G) Applied Load in kN/m2
Span in Metres
Section Type: Thick. mm Load Type: 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0
 
Single

 

0.4 Dead + Super 1.00 0.63 0.42 0.30 0.22          
  Wind Suction 0.72 0.45 0.30 0.21 0.16          
0.7 Dead + Super 2.11 1.33 0.89 0.63 0.46 0.34 0.26 0.21    
  Wind Suction 1.48 0.93 0.63 0.44 0.32 0.24 0.19 0.15    
 
Double 0.4 Dead + Super 1.44 1.05 0.70 0.49 0.36 0.27 0.21      
  Wind Suction 1.20 0.76 0.51 0.36 0.26 0.20 0.15      
0.7 Dead + Super 3.21 2.21 1.48 1.04 0.76 0.57 0.44 0.35 0.28 0.23
  Wind Suction 2.47 1.56 1.04 0.73 0.53 0.40 0.31 0.24 0.20 0.16
 
Multiple 0.4 Dead + Super 1.66 1.05 0.70 0.49 0.36 0.27 0.21 0.16 0.13 0.11
  Wind Suction 1.20 0.76 0.51 0.36 0.26 0.20 0.15 0.12 0.09 0.08
0.7 Dead + Super 3.52 2.21 1.48 1.04 0.76 0.57 0.44 0.35 0.28 0.23
  Wind Suction 2.47 1.56 1.04 0.73 0.53 0.40 0.31 0.24 0.20 0.16
 
Deflection: Dead + Super Loads = L/200
Note: All intermediate values within the limits of the table may be obtained by linear interpolation.