Proclad
1000/32 Wall Reverse Profile
Profile Proclad
The Span Tables below have been created in accordance with EN 1993-1-3 (Eurocode EC3) and calculated by the Steel Construction Institute (SCI). The values are based on a maximum permitted deflection of Span/150 under imposed load.
Load factor (working load to ultimate) 1.5 in accordance with Eurocode.
Deflection for limit of span L/150

POSITIVE loads parameters 0.5mm 0.7mm NEGATIVE loads parameters 0.5mm 0.7mm
Bottom flange in compression Bottom flange in compression
Moment capacity (kNm/m) 0.697 1.083 Moment capacity (kNm/m) 0.824 1.168
Inertia (cm4/m) 7.29 11.038 Inertia (cm4/m) 7.288 11.011
Bottom flange in tension Bottom flange in tension
Moment capacity (kNm/m) 0.824 1.168 Moment capacity (kNm/m) 0.697 1.083
Inertia (cm4/m) 7.288 11.011 Inertia (cm4/m) 7.29 11.038
Shear resistance (kN/m) 19.953 31.465 Shear resistance (kN/m) 19.953 31.465
Web crushing mid (kN/m) 4.903 9.085 Web crushing mid (kN/m) 4.903 9.085
Web crushing end (kN/m) 2.452 4.542 Web crushing end (kN/m) 2.452 4.542
Inertia gross section (cm4/m) 8.596 11.868 Inertia gross section (cm4/m) 8.596 11.868
 
Proclad 1000/32 - 0.5mm
Span/Load Table POSITIVE Working load UDL (kN/m2)
POSITIVE Span in Metres
Span
Type
Design
Case
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2
Single
Moment
4.39 3.63 3.05 2.60 2.24 1.95 1.72 1.52 1.36 1.22 1.10 1.00 0.91
Inertia
8.30 6.24 4.81 3.78 3.03 2.46 2.03 1.69 1.42 1.21 1.04 0.90 0.78
Reaction
3.27 2.97 2.72 2.51 2.34 2.18 2.04 1.92 1.82 1.72 1.63 1.56 1.49
Limiting
3.27 2.97 2.72 2.51 2.24 1.95 1.72 1.52 1.36 1.21 1.04 0.90 0.78

Double
Moment
3.72 3.07 2.58 2.20 1.90 1.65 1.45 1.29 1.15 1.03 0.93 0.84 0.77
Inertia
13.84 10.40 8.01 6.30 5.04 4.10 3.38 2.82 2.37 2.02 1.73 1.49 1.30
Reaction
2.61 2.38 2.18 2.01 1.87 1.74 1.63 1.54 1.45 1.38 1.31 1.25 1.19
Interaction
1.92 1.68 1.48 1.31 1.18 1.06 0.96 0.88 0.80 0.74 0.68 0.63 0.58
Limiting
1.92 1.68 1.48 1.31 1.18 1.06 0.96 0.88 0.80 0.74 0.68 0.63 0.58

Multiple
Moment
4.65 3.84 3.23 2.75 2.37 2.07 1.82 1.61 1.43 1.29 1.16 1.05 0.96
Inertia
13.84 10.40 8.01 6.30 5.04 4.10 3.38 2.82 2.37 2.02 1.73 1.49 1.30
Reaction
2.97 2.70 2.48 2.29 2.12 1.98 1.86 1.75 1.65 1.56 1.49 1.42 1.35
Interaction
2.27 1.98 1.75 1.56 1.40 1.26 1.15 1.05 0.96 0.88 0.81 0.75 0.70
Limiting
2.27
1.98
1.75
1.56
1.40
1.26
1.15
1.05
0.96
0.88
0.81
0.75
0.70
Proclad 1000/32 - 0.5mm
Span/Load Table NEGATIVE Working load UDL (kN/m2)
NEGATIVE Span in Metres
Span
Type
Design
Case
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2
Single
Moment
3.72 3.07 2.58 2.20 1.90 1.65 1.45 1.29 1.15 1.03 0.93 0.84 0.77
Inertia
8.31 6.24 4.81 3.78 3.03 2.46 2.03 1.69 1.42 1.21 1.04 0.90 0.78
Reaction
3.27 2.97 2.72 2.51 2.34 2.18 2.04 1.92 1.82 1.72 1.63 1.56 1.49
Limiting
3.27 2.97 2.58 2.20 1.90 1.65 1.45 1.29 1.15 1.03 0.93 0.84 0.77

Double
Moment
4.39 3.63 3.05 2.60 2.24 1.95 1.72 1.52 1.36 1.22 1.10 1.00 0.91
Inertia
13.84 10.40 8.01 6.30 5.05 4.10 3.38 2.82 2.37 2.02 1.73 1.49 1.30
Reaction
2.61 2.38 2.18 2.01 1.87 1.74 1.63 1.54 1.45 1.38 1.31 1.25 1.19
Interaction
2.05 1.80 1.59 1.42 1.27 1.15 1.05 0.96 0.88 0.81 0.75 0.69 0.64
Limiting
2.05 1.80 1.59 1.42 1.27 1.15 1.05 0.96 0.88 0.81 0.75 0.69 0.64

Multiple
Moment
5.49 4.54 3.81 3.25 2.80 2.44 2.15 1.90 1.70 1.52 1.37 1.25 1.13
Inertia
13.84 10.40 8.01 6.30 5.05 4.10 3.38 2.82 2.37 2.02 1.73 1.49 1.30
Reaction
2.97 2.70 2.48 2.29 2.12 1.98 1.86 1.75 1.65 1.56 1.49 1.42 1.35
Interaction
2.41 2.12 1.88 1.68 1.51 1.37 1.24 1.14 1.05 0.96 0.89 0.83 0.77
Limiting
2.41
2.12
1.88
1.68
1.51
1.37
1.24
1.14
1.05
0.96
0.89
0.83
0.77
Proclad 1000/32 - 0.7mm
Span/Load Table POSITIVE Working load UDL (kN/m2)
POSITIVE Span in Metres
Span
Type
Design
Case
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2
Single
Moment
6.23 5.15 4.33 3.69 3.18 2.77 2.43 2.16 1.92 1.73 1.56 1.41 1.29
Inertia
12.15 9.13 7.03 5.53 4.43 3.60 2.97 2.47 2.08 1.77 1.52 1.31 1.14
Reaction
6.06 5.51 5.05 4.66 4.33 4.04 3.79 3.56 3.36 3.19 3.03 2.88 2.75
Limiting
6.06 5.15 4.33 3.69 3.18 2.77 2.43 2.16 1.92 1.73 1.52 1.31 1.14

Double
Moment
5.78 4.77 4.01 3.42 2.95 2.57 2.26 2.00 1.78 1.60 1.44 1.31 1.19
Inertia
20.24 15.21 11.72 9.21 7.38 6.00 4.94 4.12 3.47 2.95 2.53 2.19 1.90
Reaction
4.85 4.40 4.04 3.73 3.46 3.23 3.03 2.85 2.69 2.55 2.42 2.31 2.20
Interaction
3.29 2.86 2.52 2.23 1.99 1.79 1.62 1.47 1.34 1.23 1.13 1.04 0.97
Limiting
3.29 2.86 2.52 2.23 1.99 1.79 1.62 1.47 1.34 1.23 1.13 1.04 0.97

Multiple
Moment
7.22 5.97 5.01 4.27 3.68 3.21 2.82 2.50 2.23 2.00 1.81 1.64 1.49
Inertia
20.24 15.21 11.72 9.21 7.38 6.00 4.94 4.12 3.47 2.95 2.53 2.19 1.90
Reaction
5.51 5.01 4.59 4.24 3.93 3.67 3.44 3.24 3.06 2.90 2.75 2.62 2.50
Interaction
3.90 3.40 2.99 2.66 2.38 2.14 1.94 1.76 1.61 1.48 1.36 1.26 1.17
Limiting
3.90
3.40
2.99
2.66
2.38
2.14
1.94
1.76
1.61
1.48
1.36
1.26
1.17
Proclad 1000/32 - 0.7mm
Span/Load Table NEGATIVE Working load UDL (kN/m2)
NEGATIVE Span in Metres
Span
Type
Design
Case
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2
Single
Moment
5.78 4.77 4.01 3.42 2.95 2.57 2.26 2.00 1.78 1.60 1.44 1.31 1.19
Inertia
12.17 9.14 7.04 5.54 4.43 3.60 2.97 2.48 2.09 1.77 1.52 1.31 1.14
Reaction
6.06 5.51 5.05 4.66 4.33 4.04 3.79 3.56 3.36 3.19 3.03 2.88 2.75
Limiting
5.78 4.77 4.01 3.42 2.95 2.57 2.26 2.00 1.78 1.60 1.44 1.31 1.14

Double
Moment
6.23 5.15 4.33 3.69 3.18 2.77 2.43 2.16 1.92 1.73 1.56 1.41 1.29
Inertia
20.28 15.23 11.73 9.23 7.39 6.01 4.95 4.13 3.48 2.96 2.53 2.19 1.90
Reaction
4.85 4.40 4.04 3.73 3.46 3.23 3.03 2.85 2.69 2.55 2.42 2.31 2.20
Interaction
3.41 2.97 2.61 2.32 2.07 1.86 1.69 1.53 1.40 1.29 1.18 1.10 1.02
Limiting
3.41 2.97 2.61 2.32 2.07 1.86 1.69 1.53 1.40 1.29 1.18 1.10 1.02

Multiple
Moment
7.79 6.44 5.41 4.61 3.97 3.46 3.04 2.69 2.40 2.16 1.95 1.77 1.61
Inertia
20.28 15.23 11.73 9.23 7.39 6.01 4.95 4.13 3.48 2.96 2.53 2.19 1.90
Reaction
5.51 5.01 4.59 4.24 3.93 3.67 3.44 3.24 3.06 2.90 2.75 2.62 2.50
Interaction
4.03 3.52 3.10 2.76 2.47 2.23 2.02 1.84 1.68 1.55 1.43 1.32 1.22
Limiting
4.03
3.52
3.10
2.76
2.47
2.23
2.02
1.84
1.68
1.55
1.43
1.32
1.22
SCI Assessed 'SCI Assessed Quality Mark'. This mark testifies that the Steel Construction Institute (SCI) has independently verified the technical data above.
Figures and Comments given here are given for guidance purposes only. While care has been taken to ensure accuracy Duggan Profiles & Steel Service Centre Ltd. and its related companies do not accept liability for errors / or omissions. Customers should satisfy themselves of the suitability of the products supplied or manufactured by Duggan Profiles & Steel Service Centre Ltd. for the use intended.